MakeItFrom.com
Menu (ESC)

CAB vs. CAP

Both CAB and CAP are thermoplastics. There are 22 material properties with values for both materials. Properties with values for just one material (1, in this case) are not shown.

For each property being compared, the top bar is CAB and the bottom bar is CAP.

Metric UnitsUS Customary Units

Mechanical Properties

Elongation at Break, % 50 to 55
35 to 50
Flexural Modulus, GPa 0.8 to 1.7
1.2 to 1.9
Flexural Strength, MPa 21 to 57
29 to 56
Tensile Strength: Ultimate (UTS), MPa 20 to 50
28 to 45
Tensile Strength: Yield (Proof), MPa 17 to 40
22 to 40

Thermal Properties

Glass Transition Temperature, °C 140
190
Heat Deflection Temperature At 1.82 MPa (264 psi), °C 53 to 82
65 to 80
Heat Deflection Temperature At 455 kPa (66 psi), °C 68 to 92
75 to 90
Specific Heat Capacity, J/kg-K 1460
1480
Thermal Conductivity, W/m-K 0.25
0.25
Thermal Expansion, µm/m-K 14
14
Vicat Softening Temperature, °C 90 to 120
85 to 110

Electrical Properties

Dielectric Constant (Relative Permittivity) At 1 MHz 3.6
3.6
Dielectric Strength (Breakdown Potential), kV/mm 15
15
Electrical Resistivity Order of Magnitude, 10x Ω-m 16
16

Otherwise Unclassified Properties

Density, g/cm3 1.2
1.2
Refractive Index 1.5
1.5
Water Absorption After 24 Hours, % 1.2 to 1.6
1.4 to 1.7

Common Calculations

Resilience: Ultimate (Unit Rupture Work), MJ/m3 9.5 to 26
9.1 to 22
Strength to Weight: Axial, points 4.8 to 12
6.5 to 10
Strength to Weight: Bending, points 14 to 25
17 to 23
Thermal Diffusivity, mm2/s 0.14 to 0.15
0.14